SUBJECT: Unicla compressor oil quantity
Total oil capacity of the system should equal 20% of the system refrigerant charge.
EXAMPLE 1 : If a system holds 0.75Kg of refrigerant, then 750 X 20% = 150cc of
oil. The UP/UX150 already has 160cc; therefore no additional oil is required.
EXAMPLE 2 : If a system holds 2Kg of refrigerant, then 2,000 X 20% = 400cc of oil.
The UP/UX200 already has 180cc; therefore 400 - 180 = 220cc of additional oil is required.
This information is applicable to all Unicla compressors.
Note: For additional information regarding compressor installation refer to Compressor