Service Bulletin

SCA00/001

7th September, 2000

SUBJECT:         Unicla compressor oil quantity

 

Total oil capacity of the system should equal 20% of the system refrigerant charge.

EXAMPLE 1 :      If a system holds 0.75Kg of refrigerant, then 750 X 20% = 150cc of
oil. The UP/UX150 already has 160cc; therefore no additional oil is required.

EXAMPLE 2 :      If a system holds 2Kg of refrigerant, then 2,000 X 20% = 400cc of oil.
The UP/UX200 already has 180cc; therefore 400 - 180 = 220cc of additional oil is required.

This information is applicable to all Unicla compressors.

Note: For additional information regarding compressor installation refer to Compressor
Service Information
on our website.    


 

 